docs: record removal of copied timer fields from Lazy B Wells 2 and 3
This commit is contained in:
+4
-2
@@ -16,7 +16,7 @@ All 21 page trees were opened on October 21. Native Copy inspected representativ
|
||||
| Main | main | Trend + Wells and Pumps |
|
||||
| Outflow | outflow | div + row; 127 elements |
|
||||
| Well 1 | well_1 | div + operating row + information/map row; 111 elements |
|
||||
| Well 2 | well_2 | same three-root layout; 106 elements |
|
||||
| Well 2 | well_2 | same three-root layout; 104 elements after timer removal |
|
||||
| Well 3 | well_3 | same three-root layout; includes motor/speed control |
|
||||
| Air Compressor | air | layout div + all operating root |
|
||||
| Boiler | boiler | layout div + row operating root |
|
||||
@@ -57,7 +57,9 @@ Copied operating row contains 55 elements:
|
||||
|
||||
Current flow/level chart navigator is water:aiWell3Flow_eu. Historical level navigator is water:aiWell3LvlAgg_Past24Avg, default button index 1. The information/map/report root is separate; preserve it during control-page replacement and do not publish its location details unnecessarily.
|
||||
|
||||
**Timer repair pending verified PLC tags — October 21, 2026:** rechecked production Well 3 (`well_3`). Time Since Start, element `6e6f612c-c2e5-4ee9-a468-849e6191b523`, still reads `|{register:water:wellNW1_tssTmr}| * 1000`, non-editable, HH:mm:ss, blank updateRegister. Hours, element `4e613f5b-e0e3-4526-88dd-b9a81695d75e`, still reads `|{register:water:wellNW1_totalTmr}| * 1000`, editable, writes `value / 1000` to `water:wellNW1_totalTmr`, format d [days] HH:mm. Captured both original configurations and left them unchanged. The Water System (water) register table contained 1,660 entries; searches for tss, totalTmr, runtime and wellNW1 returned no matches. The Well 3 family has no verified replacement for either timer. Existing enabled `iWell3Vol_rtDaily[0]` / `[1]` are daily counters, not established equivalents of time-since-start or lifetime Hours; units were not independently verified. `well3Power_total_onTime` exists disabled and is likewise not a verified replacement. Disabled `well3_i_UTS` has blank description, slave Well Shack 2080-LC20-20QBB, address well3.i.UTS; its role/units do not establish a timer binding. Do not invent well3_tssTmr/well3_totalTmr mappings or enable an unrelated counter. Requested the correct PLC tags, units and lifetime-counter write semantics from the user. No page/register saves, counter resets, polling changes or operational tests were performed.
|
||||
**Resolved by removal — October 21, 2026:** at the user's request, removed Time Since Start and Hours from production Well 2 (well_2) and Well 3 (well_3). Both pages had copied wellNW1 references with no verified corresponding Water System timer registers. Removed only elements 3a7413f1-6213-44be-842c-350f715ceb6d and c8a9b2ea-35d5-448b-9d68-756715e25df6 (Well 2), and 6e6f612c-c2e5-4ee9-a468-849e6191b523 and 4e613f5b-e0e3-4526-88dd-b9a81695d75e (Well 3). Saved both pages and freshly reopened: Well 2 element count 106→104; Well 3 124→122; the only removed IDs were these four and no elements were added. Runtime pages show the remaining motor controls without timer fields. Well 1 has no timer fields and was unchanged. Local native Copy backups: /tmp/lazy-b-well-timer-removal-backup.json. No PLC counters were reset, register definitions altered, or operational commands submitted. Removal supersedes the earlier request to locate replacement timer bindings; adding timers later requires verified PLC tags/units.
|
||||
|
||||
**Historical audit before removal — October 21, 2026:** rechecked production Well 3 (`well_3`). Time Since Start, element `6e6f612c-c2e5-4ee9-a468-849e6191b523`, then read `|{register:water:wellNW1_tssTmr}| * 1000`, non-editable, HH:mm:ss, blank updateRegister. Hours, element `4e613f5b-e0e3-4526-88dd-b9a81695d75e`, then read `|{register:water:wellNW1_totalTmr}| * 1000`, editable, writes `value / 1000` to `water:wellNW1_totalTmr`, format d [days] HH:mm. Captured both original configurations and left them unchanged. The Water System (water) register table contained 1,660 entries; searches for tss, totalTmr, runtime and wellNW1 returned no matches. The Well 3 family has no verified replacement for either timer. Existing enabled `iWell3Vol_rtDaily[0]` / `[1]` are daily counters, not established equivalents of time-since-start or lifetime Hours; units were not independently verified. `well3Power_total_onTime` exists disabled and is likewise not a verified replacement. Disabled `well3_i_UTS` has blank description, slave Well Shack 2080-LC20-20QBB, address well3.i.UTS; its role/units do not establish a timer binding. Do not invent well3_tssTmr/well3_totalTmr mappings or enable an unrelated counter. Initially requested correct PLC tags, units and lifetime-counter write semantics; the user subsequently chose removal instead. No page/register saves, counter resets, polling changes or operational tests were performed.
|
||||
|
||||
## Valve, compressor and boiler
|
||||
|
||||
|
||||