Update to Weidmueller 4.12.1 - I think, codesys still says 4.12.0
Start on overview screen
This commit is contained in:
@@ -0,0 +1 @@
|
|||||||
|
,CLARENCE-PC/c,Clarence-PC,13.05.2026 14:23,file:///C:/Users/c/AppData/Roaming/LibreOffice/4;
|
||||||
@@ -152,4 +152,29 @@ Device.CR_Barn5.atAlarmDescriptions g.inlet1Pos.faults.chan g.inlet1Pos.faults.c
|
|||||||
Device.CR_Barn5.atAlarmDescriptions g.inlet2Pos.faults.over g.inlet2Pos.faults.over
|
Device.CR_Barn5.atAlarmDescriptions g.inlet2Pos.faults.over g.inlet2Pos.faults.over
|
||||||
Device.CR_Barn5.atAlarmDescriptions g.inlet2Pos.faults.under g.inlet2Pos.faults.under
|
Device.CR_Barn5.atAlarmDescriptions g.inlet2Pos.faults.under g.inlet2Pos.faults.under
|
||||||
Device.CR_Barn5.atAlarmDescriptions g.inlet2Pos.faults.chan g.inlet2Pos.faults.chan
|
Device.CR_Barn5.atAlarmDescriptions g.inlet2Pos.faults.chan g.inlet2Pos.faults.chan
|
||||||
Device.Application.atAlarmDescriptions ' '
|
Device.Application.atAlarmDescriptions g.fan_36E.fault g.fan_36E.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.fan_36W.fault g.fan_36W.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.heat.fault g.heat.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.inlet1Open.fault g.inlet1Open.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.inlet1Close.fault g.inlet1Close.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.lights.fault g.lights.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.inlet2Open.fault g.inlet2Open.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.inlet2Close.fault g.inlet2Close.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.waterSol.fault g.waterSol.fault
|
||||||
|
Device.Application.atAlarmDescriptions g.temp1.sensorFault g.temp1.sensorFault
|
||||||
|
Device.Application.atAlarmDescriptions g.temp2.sensorFault g.temp2.sensorFault
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.faults.over g.temp3.faults.over
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.faults.under g.temp3.faults.under
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.faults.chan g.temp3.faults.chan
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.sensorFault g.temp3.sensorFault
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.limits.hihi.alm g.temp3.limits.hihi.alm
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.limits.hi.alm g.temp3.limits.hi.alm
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.limits.lo.alm g.temp3.limits.lo.alm
|
||||||
|
Device.Application.atAlarmDescriptions g.temp3.limits.lolo.alm g.temp3.limits.lolo.alm
|
||||||
|
Device.Application.atAlarmDescriptions g.fdHopMaleLc.faults.over g.fdHopMaleLc.faults.over
|
||||||
|
Device.Application.atAlarmDescriptions g.fdHopMaleLc.faults.under g.fdHopMaleLc.faults.under
|
||||||
|
Device.Application.atAlarmDescriptions g.fdHopMaleLc.faults.chan g.fdHopMaleLc.faults.chan
|
||||||
|
Device.Application.atAlarmDescriptions g.fdHopMaleLc.limits.hihi.alm g.fdHopMaleLc.limits.hihi.alm
|
||||||
|
Device.Application.atAlarmDescriptions g.fdHopMaleLc.limits.hi.alm g.fdHopMaleLc.limits.hi.alm
|
||||||
|
Device.Application.atAlarmDescriptions g.fdHopMaleLc.limits.lo.alm g.fdHopMaleLc.limits.lo.alm
|
||||||
|
Device.Application.atAlarmDescriptions g.fdHopMaleLc.limits.lolo.alm g.fdHopMaleLc.limits.lolo.alm
|
||||||
|
|||||||
|
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
LFS
BIN
Binary file not shown.
BIN
Binary file not shown.
Binary file not shown.
BIN
Binary file not shown.
@@ -1,4 +0,0 @@
|
|||||||
c
|
|
||||||
CLARENCE-PC
|
|
||||||
15412
|
|
||||||
639142823716781585
|
|
||||||
Binary file not shown.
Binary file not shown.
Binary file not shown.
@@ -1,6 +1,6 @@
|
|||||||
Codesys v3.5 sp21 patch 1
|
Codesys v3.5 sp22 patch 1
|
||||||
VPN IP: 10.5.1.217
|
VPN IP: 10.5.1.217
|
||||||
Chipsee with odot I/O
|
Weidmueller WL2000 PLC, odot IO, Chipsee screen
|
||||||
|
|
||||||
To update alarm text, while logged into plc with codesys, view the alarm manager debug and copy the pathList string value. Remove the starting and ending quotes then paste this into the AlarmDescriptions.ods Libra Office Calc. Then run the macro to copy any new alarms to the alarm list.
|
To update alarm text, while logged into plc with codesys, view the alarm manager debug and copy the pathList string value. Remove the starting and ending quotes then paste this into the AlarmDescriptions.ods Libra Office Calc. Then run the macro to copy any new alarms to the alarm list.
|
||||||
Now from in codesys, import the generated AlarmDescriptions.csv file into the atAlarmDescriptions text list - from in the list right click to get the menu options to import.
|
Now from in codesys, import the generated AlarmDescriptions.csv file into the atAlarmDescriptions text list - from in the list right click to get the menu options to import.
|
||||||