clarence
|
7918021599
|
Adjust valve position sensors debounce to 0 ms for all valvles sensors, some where at 100ms. Save persistent vars to recipe
|
2026-10-12 11:41:18 -06:00 |
|
clarence
|
77518c8ffe
|
Update be2 speed lolo setpoint, save persistent to recipe
|
2026-10-10 21:53:21 -06:00 |
|
clarence
|
a1bf1b6629
|
Update vfd auto speed settings to be the same as the manual speed settings
|
2026-10-09 09:24:25 -06:00 |
|
clarence
|
9a1c8f147d
|
Copy development to at site, verify goes on line, backup persistent, delete development folder
|
2026-10-06 08:14:36 -06:00 |
|
clarence
|
ee55110bdc
|
Update and download development for vfd on dc7, and only running gen2 for drying motors. Need to move development to atsite
|
2026-10-05 20:58:10 -06:00 |
|
clarence
|
7ab7f33418
|
Update program in Development to handle dc4 vfd, go online with at site and save persistent vars to file. Delete unused project files.
|
2026-10-05 14:38:45 -06:00 |
|
clarence
|
fa339404b4
|
HMI changes for cleaning auger downloaded, saved persistent vars to recipe
|
2026-09-22 16:31:43 -06:00 |
|
clarence
|
236545a170
|
Add HMI updates for cleaning auger - not downloaded
|
2026-09-21 16:52:44 -06:00 |
|
clarence
|
3dd15da445
|
Bin level alarms, gen control logic
|
2026-09-18 16:49:14 -06:00 |
|
clarence
|
fa520f34b8
|
Update seq control and gen1 and gen 2 logic
|
2026-09-17 17:33:55 -06:00 |
|
clarence
|
6fefa5f2fb
|
Updated dynagen to send start command repeatedly until gen is not stopped. Update stop delay to use the sequence stop delay. Not installed at site
|
2026-09-17 14:40:40 -06:00 |
|
clarence
|
67cfa08490
|
goes online from laptop
|
2026-09-17 13:16:22 -06:00 |
|
clarence
|
684e07b154
|
go online, download persistent
|
2026-09-17 10:03:26 -06:00 |
|
clarence
|
919b927ca8
|
as left at site, persistant vars will include running motors, bins names updated
|
2026-09-14 09:19:52 -06:00 |
|
clarence
|
cd41f93d6a
|
Scale comms test
|
2026-09-14 06:54:20 -06:00 |
|
clarence
|
011c9dd998
|
Trying to fix distributor manual position list
|
2026-09-11 20:22:12 -06:00 |
|
clarence
|
08df0b8962
|
task tuning, plus other
|
2026-09-10 20:23:17 -06:00 |
|
clarence
|
0d36523270
|
lots of little things
|
2026-09-09 19:38:06 -06:00 |
|
clarence
|
2042f830c6
|
Updated distributor positions
|
2026-09-08 18:14:11 -06:00 |
|
clarence
|
302726c252
|
valve two working, gen comms ok
|
2026-09-07 18:51:37 -06:00 |
|
clarence
|
35901e57a1
|
gen comms updated
|
2026-09-07 11:47:22 -06:00 |
|
clarence
|
d9f93e83b6
|
Lots of alarms working, hmi looking good, nothing further on dryer
|
2026-09-04 17:47:47 -06:00 |
|
clarence
|
86ed9c3119
|
transfer sequnce and stops
|
2026-09-03 18:25:11 -06:00 |
|
clarence
|
e59b6d427f
|
Update alarm manager history to show alm/rtn
|
2026-09-03 08:34:18 -06:00 |
|
clarence
|
22b5f639b5
|
Working on receiving control
|
2026-09-02 17:57:23 -06:00 |
|
clarence
|
e5b3f75a94
|
Dynagen working
|
2026-09-01 15:02:39 -06:00 |
|
clarence
|
05baeef885
|
Working on generator control
|
2026-08-31 17:17:01 -06:00 |
|
clarence
|
9daeae8911
|
Working on rigmar control and simulation
|
2026-08-28 17:01:43 -06:00 |
|
clarence
|
56b36ebc49
|
Menuing and alarms working well
|
2026-08-28 13:40:44 -06:00 |
|
clarence
|
b07e34d85b
|
Dropdown menu and alarms
|
2026-08-28 09:12:24 -06:00 |
|
clarence
|
df309fd705
|
Working on alarms - descriptions not working
|
2026-08-27 18:21:47 -06:00 |
|
clarence
|
a2288e2eaa
|
Alarm manager working better
|
2026-08-27 09:51:16 -06:00 |
|
clarence
|
8b35e203e4
|
Gates, alarm manager and tasks
|
2026-08-26 18:24:43 -06:00 |
|
clarence
|
2d9b54083f
|
Working on gate control
|
2026-08-25 15:42:26 -06:00 |
|
clarence
|
243acd5bb4
|
Valves with hmi seem to be working
|
2026-08-24 20:48:48 -06:00 |
|
clarence
|
1833df215d
|
Valve logic update with new manual mode scheme
|
2026-08-24 14:31:53 -06:00 |
|
clarence
|
776d1df617
|
Working on Sequence cleanup and valve operation / HMI
|
2026-08-19 17:17:26 -06:00 |
|
clarence
|
ffc6eeb326
|
Prior to moving to new codeys version
|
2026-08-18 15:34:30 -06:00 |
|
carlos
|
8dfdd041ad
|
not sure - latest
|
2026-08-12 17:15:57 -06:00 |
|
carlos
|
4c4473b4b9
|
latest
|
2026-08-11 17:19:43 -06:00 |
|
carlos
|
839f372f3e
|
working on actuator for timed position
|
2026-08-10 17:11:23 -06:00 |
|
carlos
|
0800a289fa
|
cr-updates
|
2026-08-07 17:09:45 -06:00 |
|
carlos
|
0ef06e826c
|
cr latest
|
2026-08-06 16:14:00 -06:00 |
|
carlos
|
2a7c0b393d
|
cr-latest
|
2026-08-05 17:12:15 -06:00 |
|
carlos
|
4c0d858385
|
latest
|
2026-08-04 18:17:03 -06:00 |
|
clarence
|
a77ab19a93
|
Shop testing complete v2 - dryer motors
|
2026-07-31 16:25:14 -06:00 |
|
clarence
|
91a25e5693
|
Testing in shop complete
|
2026-07-31 15:29:42 -06:00 |
|
clarence
|
1b52415847
|
Updated td350
|
2026-07-31 12:14:33 -06:00 |
|
clarence
|
b9b35586e9
|
Commited part way through testing, cntr working
|
2026-07-31 11:55:57 -06:00 |
|
carlos
|
96bce22e80
|
latest
|
2026-07-30 10:16:02 -06:00 |
|