clarence pushed to master at Auto/aao-main-codesys 2026-10-12 17:41:23 +00:00
7918021599 Adjust valve position sensors debounce to 0 ms for all valvles sensors, some where at 100ms. Save persistent vars to recipe
clarence pushed to master at Auto/aao-main-codesys 2026-10-11 03:53:25 +00:00
77518c8ffe Update be2 speed lolo setpoint, save persistent to recipe
clarence pushed to master at Auto/aao-main-codesys 2026-10-09 15:24:31 +00:00
a1bf1b6629 Update vfd auto speed settings to be the same as the manual speed settings
clarence pushed to master at Auto/aao-main-codesys 2026-10-06 14:14:41 +00:00
9a1c8f147d Copy development to at site, verify goes on line, backup persistent, delete development folder
clarence pushed to master at Auto/aao-main-codesys 2026-10-06 02:58:16 +00:00
ee55110bdc Update and download development for vfd on dc7, and only running gen2 for drying motors. Need to move development to atsite
clarence pushed to master at Auto/aao-main-codesys 2026-10-05 20:38:53 +00:00
7ab7f33418 Update program in Development to handle dc4 vfd, go online with at site and save persistent vars to file. Delete unused project files.
clarence pushed to master at Auto/aao-main-codesys 2026-09-22 22:31:50 +00:00
fa339404b4 HMI changes for cleaning auger downloaded, saved persistent vars to recipe
clarence pushed to master at Auto/aao-main-codesys 2026-09-21 22:52:51 +00:00
236545a170 Add HMI updates for cleaning auger - not downloaded
clarence pushed to master at Auto/aao-main-codesys 2026-09-18 22:49:21 +00:00
3dd15da445 Bin level alarms, gen control logic
clarence pushed to master at Auto/aao-main-codesys 2026-09-17 23:34:02 +00:00
fa520f34b8 Update seq control and gen1 and gen 2 logic
clarence pushed to master at Auto/aao-main-codesys 2026-09-17 20:40:46 +00:00
6fefa5f2fb Updated dynagen to send start command repeatedly until gen is not stopped. Update stop delay to use the sequence stop delay. Not installed at site
clarence pushed to master at Auto/aao-main-codesys 2026-09-17 19:16:30 +00:00
67cfa08490 goes online from laptop
clarence pushed to master at Auto/aao-main-codesys 2026-09-17 16:03:39 +00:00
684e07b154 go online, download persistent
clarence pushed to master at Auto/aao-main-codesys 2026-09-14 15:20:39 +00:00
919b927ca8 as left at site, persistant vars will include running motors, bins names updated
clarence pushed to master at Auto/aao-main-codesys 2026-09-14 12:55:37 +00:00
cd41f93d6a Scale comms test
clarence pushed to master at Auto/aao-main-codesys 2026-09-12 02:22:56 +00:00
011c9dd998 Trying to fix distributor manual position list
clarence pushed to master at Auto/aao-main-codesys 2026-09-11 02:23:55 +00:00
08df0b8962 task tuning, plus other
clarence pushed to master at Auto/aao-main-codesys 2026-09-10 01:38:57 +00:00
0d36523270 lots of little things
clarence pushed to master at Auto/aao-main-codesys 2026-09-09 00:15:30 +00:00
2042f830c6 Updated distributor positions
clarence pushed to master at Auto/aao-main-codesys 2026-09-08 00:52:33 +00:00
302726c252 valve two working, gen comms ok